TWO TECHNICAL LEARNING PATHS

Choose the reference.
Learn the work.

Practical insulation training informed by NORSOK M-004 and the CINI Manual. Select the reference used on your project, then ask us about training and assessment.

Practical installation of insulated pipe cladding01 / TRAINING PATH
TECHNICAL REFERENCE

NORSOK M-004

Piping and equipment insulation

Learn how to read insulation classes, select approved systems, inspect installation details and document quality for industrial projects.

  • Hot and cold insulation classes and material selection
  • Practical work from complex details to Armaflex tubing
  • Cladding, moisture control and inspection
Explore NORSOK M-004
Hands-on technical pipe insulation training02 / TRAINING PATH
TECHNICAL REFERENCE

CINI

Industrial insulation manual

Learn to use CINI guidance and details for industrial insulation of pipes and equipment, from material choice to finishing and quality checks.

  • Hot, cold and cryogenic systems
  • Supports, terminations and vapour stops
  • Hands-on installation, finishing and quality control
Explore CINI
HANDS-ON LEARNING

Learn it. Build it. Check it.

We explain the insulation classes and the difference between hot and cold insulation. Then we practise correct installation, starting with demanding pipework details and working through to simpler applications such as Armaflex tubing. These skills can be applied on future projects.

Call +370 620 88002 ↗
FIELD QUALITY / PRACTICAL TRAINING

See the difference.
Learn the detail.

Real examples make defects easier to recognise. We teach installers to measure and form pipe cladding, fit elbows and joints, control water entry and inspect the finished work against the approved IPS.

Damaged, loose metal cladding on a pipe elbow with visible openings and vegetation around the joint
LEFT / DO NOT COPY

Damaged cladding and open details

The metal jacket is visibly damaged and lifted at the elbow. Open or deteriorated details need inspection and repair to restore protection against water entry.

More closely fitted metal cladding sections on an insulated pipe bend
RIGHT / FITTING EXAMPLE

Carefully formed and fitted sections

The bend shows a closer, more regular fit. In training we also check the overlaps, fixings, end details and drainage required by the approved drawing and IPS before accepting any installation.

These photographs compare visible workmanship only. A full quality acceptance requires checks of concealed insulation and the project specification.

Independent training: These paths use NORSOK M-004 and CINI as technical references. They are not courses authorised or certified by Standards Norway, CINI or FROSIO. The on-site training and assessment format, price and any completion document are agreed before booking.